POLIESOL® Aluminio XZ1 (S) AL
POLIESOL® Aluminio XZ1 (S) AL
Cabo de alumínio, livre de halogênios, para redes de distribuição.
Leia maisNexans XZ1 Aluminio (S) 0,6/1kV 1x16 mm²
Referência Nexans 10199222
- Packaging: Coil (m)
- Conductor shape: -
- Nominal outer diameter: - mm
- Conductor cross-section: 16 mm²
- Approximate weight: 107 kg/km
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Voltage drop, single phase: - V/A.km
- Cable flexibility: -
Nexans XZ1 Aluminio (S), 1x25 mm²
Referência Nexans 10164297
- Packaging: Coil (m)
- Conductor shape:
- Nominal outer diameter: 10,7 mm
- Conductor cross-section: 25 mm²
- Approximate weight: 136 kg/km
- Permissible current rating in open air: 112 A
- Permissible current rating when buried: 115 A
- Voltage drop, single phase: 2,2 V/A.km
- Cable flexibility: Class 2
Nexans XZ1 Aluminio (S) 0,6/1kV 1x35 mm²
Referência Nexans 10199244
- Packaging: Coil (m)
- Conductor shape: -
- Nominal outer diameter: - mm
- Conductor cross-section: 35 mm²
- Approximate weight: 184 kg/km
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Voltage drop, single phase: - V/A.km
- Cable flexibility: -
Nexans XZ1 Aluminio (S), 1x50 mm²
Referência Nexans 10196368
- Packaging: Coil (m)
- Conductor shape: Circular
- Nominal outer diameter: 12,8 mm
- Conductor cross-section: 50 mm²
- Approximate weight: 210 kg/km
- Permissible current rating in open air: 168 A
- Permissible current rating when buried: 167 A
- Voltage drop, single phase: 1,25 V/A.km
- Cable flexibility: Class 2
Nexans XZ1 Aluminio (S) 0,6/1kV 1x70 mm²
Referência Nexans 10199245
- Packaging: Coil (m)
- Conductor shape: -
- Nominal outer diameter: - mm
- Conductor cross-section: 70 mm²
- Approximate weight: 308 kg/km
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Voltage drop, single phase: - V/A.km
- Cable flexibility: -
Nexans XZ1 Aluminio (S), 1x95 mm²
Referência Nexans 10196369
- Packaging: Coil (m)
- Conductor shape: Circular
- Nominal outer diameter: 16,6 mm
- Conductor cross-section: 95 mm²
- Approximate weight: 370 kg/km
- Permissible current rating in open air: 258 A
- Permissible current rating when buried: 247 A
- Voltage drop, single phase: 0,57 V/A.km
- Cable flexibility: Class 2
Nexans XZ1 Aluminio (S) 0,6/1kV 1x120 mm²
Referência Nexans 10199246
- Packaging: Coil (m)
- Conductor shape: -
- Nominal outer diameter: - mm
- Conductor cross-section: 120 mm²
- Approximate weight: 487 kg/km
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Voltage drop, single phase: - V/A.km
- Cable flexibility: Semi-rigid
Nexans XZ1 Aluminio (S), 1x150 mm²
Referência Nexans 10196370
- Packaging: Coil (m)
- Conductor shape: Circular
- Nominal outer diameter: 19,9 mm
- Conductor cross-section: 150 mm²
- Approximate weight: 548 kg/km
- Permissible current rating in open air: 344 A
- Permissible current rating when buried: 316 A
- Voltage drop, single phase: 0,47 V/A.km
- Cable flexibility: Class 2
Nexans XZ1 Aluminio (S) 0,6/1kV 1x185 mm²
Referência Nexans 10199247
- Packaging: Coil (m)
- Conductor shape: -
- Nominal outer diameter: - mm
- Conductor cross-section: 185 mm²
- Approximate weight: 689 kg/km
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Voltage drop, single phase: - V/A.km
- Cable flexibility: -
Nexans XZ1 Aluminio (S), 1x240 mm²
Referência Nexans 10164296
- Packaging: Coil (m)
- Conductor shape: Circular
- Nominal outer diameter: 24,7 mm
- Conductor cross-section: 240 mm²
- Approximate weight: 860 kg/km
- Permissible current rating in open air: 461 A
- Permissible current rating when buried: 413 A
- Voltage drop, single phase: 0,32 V/A.km
- Cable flexibility: Class 2
Descrição
Descrição
Padrões
-
ProductNexans specification
Application
RV aluminium cables can be used in all low voltage power installations.
Safety cable(S) with characteristics of no flame spread, halogen free low acidity and corrosiveness of gases low opacity of smoke emitted during combustion.
Installation and design
These cables can be fixed on cable trays, within conduits or fixed to walls. They also can be buried directly with extra mechanical protection.
Core colours
- 1 core = Black
Características
Características
Construction characteristics
Construction characteristics
Características dimensionais
Características dimensionais
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Recursos
Recursos
Informações de venda e entrega
Marking
Nexans - XZ1 (S) 1x
Section(mm²) AL - Year of fabrication - AENOR
Nossos sites