H07RN-F 12G1.5 cut to length
Referência Nexans 10056182
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Conductor cross-section: 1,5 mm²
- Number of cores: 12
- Maximum outer diameter: 22,14 mm
- Minimum outer diameter: 17,6 mm
H07RN-F 12G2,5 MBH GL3000
Referência Nexans 10044033
- Packaging: Cut to length (m)
- With Green/Yellow core: Yes
- Conductor cross-section: 2,5 mm²
- Number of cores: 12
- Maximum outer diameter: 26,2 mm
- Minimum outer diameter: 20,6 mm
H07RN-F 1X150 MBH GL2000
Referência Nexans 10056129
- Packaging: Cut to length (m)
- With Green/Yellow core: No
- Conductor cross-section: 150 mm²
- Number of cores: 1
- Maximum outer diameter: 31,4 mm
- Minimum outer diameter: 25,2 mm
H07RN-F 1X95 MBH GL3000
Referência Nexans 10056088
- Packaging: Cut to length (m)
- With Green/Yellow core: No
- Conductor cross-section: 95 mm²
- Number of cores: 1
- Maximum outer diameter: 26,0 mm
- Minimum outer diameter: 20,8 mm
H07RN-F 1x10 cut to length
Referência Nexans 10056059
- Packaging: Cut to length (m)
- With Green/Yellow core: No
- Conductor cross-section: 10 mm²
- Number of cores: 1
- Maximum outer diameter: 11,9 mm
- Minimum outer diameter: 9,5 mm
Descrição
Descrição
Padrões
-
ProductEN 50525-2-21; HD 22.4; HD 516; IEC 60245-4 type 66; NF C32-102-4
Application
H07RN-F flexible cable is intended for installations with moving equipments, electric appliances and for building sites also for motors in lifting appliances -machine tools, etc ... The cable may be rated up to 0,6/1 kV where the installation has built-in protection.
This range of cables is recommended in dry, damp or wet workshops, indoor and outdoor, for example in explosive atmosphere(as ATEX) according to regulation of the country and with some additional recommendations and also for industrial devices and agricultures workshops ...
This cable can be used in refrigerating installations.
Installation
Conductors laid up
Assembled conductors.
Nota
Max continuous operating conductor temperature in normal use :
+60°C (in every case of mobile installation)
+85°C (in fixed and protected installation)
+200°C ( in short circuit )
Permissible current rating is measured for an ambient temperature of 30°C and a maximum operating and conductor temperature of 60°C . For other temperature please refer to correction factors .
European Directive RoHS : Compliant
SY+ : French directive for lead free materials in materials.
Características
Características
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Recursos
Recursos
Documentação
Informações de venda e entrega
Marking
USE <'HAR> H07RN-F N (x or G) S mm²
N = number of cores
G = with Green-Yellow
x = without Green-Yellow
S = section in mm²